An architect is helping an organization with the Physical Design of an NSX-T Data Center solution. This information was…

An architect is helping an organization with the Physical Design of an NSX-T Data Center solution. This information was gathered during a workshop: ✑ Any proposed solution must provide low latency. ✑ Any proposed solution must provide high throughput. ✑ Customer is running stock trading applications. Which two selections should the architect recommend to meet high-performance workload requirements? (Choose two.)
  • A.Leverage ESXi as the compute host.
  • B.Use LACP for all uplink profiles.
  • C.Leverage KVM as the compute host.
  • D.Enable enhanced data path mode on the N-VDS.
  • E.Enable latency sensitivity mode on the N-VDS.
Explanation
A & D are correct. N-VDS and VDS support the following modes: Standard: Provide forwarding capabilities on both KVM and ESX transport nodes and does not require a specialized hardware. Enhanced Datapath: Available for ESXi transport nodes only and provide Enhanced Network Stack (ENS) targeted for Network Functions Virtualization (NFV) applications that require a faster performance data path. Take from NSX-T ICM 3.0 Lecture Manual

Reference: examtopics_top_comment